C&I Energy Storage EMS Solution

A C&I Energy Storage management system powered by EMU300, making energy control more reliable and project delivery simpler.

  • Lower O&M Cost
  • Reverse-power and Demand-overrun Protection
  • Multi-source Revenue Analytics
<100msResponse time
One cabinetOne controller, scalable
9Core strategies
7×24Proactive alarms
C&I Energy Storage EMS Solution Image
C&I Energy Storage EMS SolutionLower O&M CostReverse-power and Demand-overrun ProtectionMulti-source Revenue Analytics
C&I Storage Solution

C&I energy storage: a single closed loop for control, O&M and revenue

A C&I Energy Storage management system powered by EMU300, making energy control more reliable and project delivery simpler.

Lower O&M CostReverse-power and Demand-overrun ProtectionMulti-source Revenue Analytics
C&I Energy Storage EMS Solution Scenario Image
A single closed loop for control, O&M and revenue
<100ms Control Response
30 Units Ring-network Cabinets
9 Operating Strategies

C&I Energy Storage Project Challenges

Focused on the four key phases of deployment, operation, O&M and revenue.

One controller per cabinet, ring-network redundancy and flexible on-demand expansion.

Customer Situation

High Deployment Cost

Transformer expansion is expensive and grid-connection approval takes too long.

Business Impact
Higher CAPEX
Conversation Starter
Deployment
Product Approach

EMU300 Modular Expansion

Add storage cabinets through a standard ring-network design without redesigning the site.

  • One controller per cabinet
  • Ring-network redundancy
  • Faster site delivery
Customer Situation

Limited Intelligent Dispatch

Manual scheduling lowers PV self-consumption and operating efficiency.

Business Impact
Lower operating value
Conversation Starter
Operations
Product Approach

EMU300 Unified Dispatch

Automated peak shaving, reverse-power and demand-overrun strategies execute at the edge.

  • Automatic switching
  • Local execution
  • Traceable results
Customer Situation

Delayed Fault Detection

Without a unified platform, device and alarm entry points remain fragmented.

Business Impact
Higher O&M effort
Conversation Starter
O&M
Product Approach

EMU + FeiCloud Alarm Review

Centralized device access, alarms and remote operations review shorten the path from fault to action.

  • Unified device access
  • Alarm history
  • Remote O&M Review
Customer Situation

ROI Is Hard to Quantify

Fine-grained monitoring and multi-source revenue analysis are missing.

Business Impact
Unclear payback
Conversation Starter
Revenue
Product Approach

EMU + FeiCloud Revenue Reports

Daily, weekly, monthly and annual revenue reports make investment criteria traceable.

  • Revenue breakdown
  • Periodic reports
  • Investment review

A cloud-edge coordinated system connecting project deployment, site control, cloud review and long-term operations.

System Architecture

Cloud-edge-device C&I Energy Storage Architecture

On-site equipment connects to the EMU300, strategies are executed at the edge, and monitoring, alarms and revenue are synced to FeiCloud.

Field Data Edge Execution Cloud Collaboration Operation Review
Application & Operation Layer Dashboards, reports, apps and dispatch portals
Operations Portal

Dashboards and apps provide unified access to site status, devices, alarms and reports.

Platform Collaboration Layer FeiCloud, EMS cabinet and strategy library
FeiCloud Platform

Provides second-level monitoring, tiered alarms, revenue analysis and strategy configuration.

Edge Control Layer EMU controller, local strategy and safety interlock
EMU300 Edge Layer

Responds in under 100 ms, executes nine operating strategies and provides ring-network redundancy.

Field Device Layer PCS, BMS, meters, PV-storage-charging-diesel and loads
Field Device Layer

PCS, BMS, meters, PV, charging piles and environmental sensors connect to the site.

Control Strategy

Key Control Strategies

Modular Expansion

Add a cabinet and it runs immediately without stopping the site or replacing the controller.

  • One controller per cabinet
  • Plug and play

Core Operating Strategies

Peak shaving, reverse-power protection, demand-overrun protection and microgrid strategies switch automatically.

  • Automatic switching
  • Traceable settings

Grid-connection Monitoring and Protection

Monitor grid-point power in real time and adjust charge/discharge to control reverse power and demand peaks.

  • Load tracking
  • Reverse-power protection

Revenue Analysis and Proactive Alarms

Tiered alarms and multi-source revenue reports close the loop from daily to annual review.

  • Second-level refresh
  • Tiered alarms
Solution Value

Solution Value

<100ms Control Response

Local strategies execute in milliseconds.

30 Units Ring-network Cabinets

It supports ring-network redundancy and elastic expansion for standard energy storage cabinets.

9 Operating Strategies

Covers peak shaving, reverse-power protection and demand control.

≥85% Self-consumptiontarget

It increases the revenue from local PV consumption.

Recommended Device

Recommended Device Models

EMU 300 Product Image
EMU300

Single-cabinet / Light C&I

Applicable scale: 200 kWh to 2 MWh | Response time: <100 ms | Installation method: wall-mounted | Operating temperature: -30℃ to 55℃. Purpose-built for C&I energy storage, it integrates edge computing, intelligent dispatch and data acquisition. It can manage a single cabinet independently, or interconnect multiple cabinets via a ring-network topology to achieve cabinet parallelisation and networking; the ring-network architecture provides link redundancy, so a single-point link failure does not affect overall system communication.